Sump with a side overflow device sumps do require an increase in the depth of flow in the box gutter and gutters are to be fitted with either.
Sump box gutter.
Down pipe must be.
For the associated box gutter outlet.
The mod tec gutta sump can be fit ted simply from within the fitted box gutter this assists the accurate locating of the sump.
A box gutter is defined as a graded channel generally of a rectangular shape for the conveyance of rainwater within the building footprint including adjacent to a wall or parapet.
The minimum size of a sump is 400mm x 200mm minimum width of box gutter and 150mm deep.
The outlet must be no further than the diameter of the outlet to the centre of the outlet.
Sumps are usually attached between a box gutter and the downpipe.
Box gutters must be straight no bends.
Must have a constant slope between 1 40 and 1 200.
Code box gutter requirements the minimum width allowed for domestic projects is 200mm.
Sides must be vertical.
Sumps can be made to order but are commonly manufactured in either 100mm and 150mm depths.
It is easier to mark and cut the spigothole prior to fitting the sumpinto the box gutter.
Overflow devices need to discharge to the atmosphere in such a way as to prevent damage to buildings and property.
A rainwater sump catches any debris or unwanted materials from travelling down the drain pipe and into any drains.
The spigotcan also be fitted from inside the sump this allows the downpipe to be fitted up to the sump.
They collect storm water before it is carried away by the downpipe and they also serve to catch any debris before it enters the downpipe.
But it can be used for elsewhere in the world if you know the design rainfall intensity requirements for your area.
For commercial projects the minimum allowable width is 300mm.